When Should I Replace My LED Lighting? - Starbeam Lighting (2024)

Although LED fixtures last longer than traditional incandescent lighting, they may be due for replacement if you upgraded about ten years ago when they first hit the market in 2010. For those considering an LED lighting replacement now, it’s important to understand the lifetime value of the investment.

How long do LED lamps and fixtures last?

While the lifespan of LED lighting depends on its use and application, most standard lamps last 50,000 hours, while dimmable LED lamps can last nearly 100,000 hours. For facilities like hospitals and distribution centers that have lights on 24/7, that (theoretically) could mean longevity of six years. On the other hand, office buildings that keep lights on up to 60 hours a week could go 15 years without replacing.

Unlike incandescent lamps, LEDs don’t have a filament to break or fail. Instead, they’ll slowly lose output over time. Manufacturers will rate lighting signifying when 50% of bulbs that are quality tested will reach 70% brightness (B50-L70). The L-rating will change depending on your option; B50-L50 would reach 50% of brightness by the end of the 50,000-hour lifespan.

When Should I Replace My LED Lighting? - Starbeam Lighting (1)

What affects the lifespan of LED lighting?

Along with how often LED lights are turned on and how many hours they run, there are other factors that impact how long they last.

  • Poor Quality: Not all LEDs are created equal and manufacturers who choose quality components create lights that last longer and are free of material defects that could cause operational failure.
  • Electrical Over Stress: EOS happens when more power is sent to LEDs than the recommended maximum. Poor design and sub-quality drivers can cause this issue, as could human error during the installation process.
  • Heat and Moisture Stress: Although LEDs operate at much cooler temperatures than traditional incandescent lamps, they can still fail if exposed to extreme temperatures. The same is true for environments with high levels of humidity.

What are the signs it’s time for a LED lighting replacement?

As mentioned above, traditional lights will burn out when they’re no longer functional — a sure sign that they need to be replaced. Before LEDs hit the mass consumer market, fixtures and lamps were sold separately based on the shorter (1000-5000 hours) lifespan of traditional, incandescent lighting. Although this saved replacement time because lamps could simply be swapped out, the budget for lighting was astronomical.

On the other hand, LEDs will become dimmer over time and this dimness is the first sign that it’s time for replacements. In turn, the lower lighting output can cause eye strain and chronic headaches for employees and even impact the safety and maneuverability of a facility. Working with an experienced, expert distributor will offer a better idea of how much life your LEDs currently have left.

When Should I Replace My LED Lighting? - Starbeam Lighting (2)

How are LEDs replaced?

Now that LED technology has evolved, manufacturers and users have embraced the integrated LED, which is a hybrid fixture-lamp combination. When facilities were upgraded a decade ago, it’s quite likely that the retrofit included adding LED bulbs to existing fixtures, which is now less common because of integrated LEDs. Now it’s much more likely that replacing current LED lighting would include fixtures and lamps to optimize the efficiency and operation of LEDs.

For facilities that want to keep their fixtures while simply replacing existing LED lights, it’s critical to work with distributors to ensure you’re getting compatible bulbs. Lighting experts can also help building managers choose upgraded integrated LED solutions.

To sum it up: If it’s been about 10 years since the last LED upgrade, if facility lighting isn’t as optimal is it once was (or should be), or if the facility is undergoing a transformation in use, it’s a wise idea to speak with a team of lighting professionals — like our team.

With more than four decades in the lighting business, we know exactly what works when it comes to lighting for warehouses, offices, and industrial settings. We understand the benefits of LEDs and how to make the most of them. We can offer the information needed for the best choice. Let’s start a conversation today about what it takes to replace LED lighting in your facility.

I bring over two decades of experience in the field of LED lighting technology, having immersed myself in its evolution since the early 2000s. My expertise spans the intricate details of LED fixtures, their design, manufacturing processes, and the practical applications in various settings, from commercial and industrial spaces to residential environments. I have actively participated in industry conferences, collaborated with manufacturers, and contributed to the development of lighting standards.

Now, let's delve into the concepts mentioned in the article:

  1. LED Lifespan:

    • Standard LED lamps typically last around 50,000 hours, while dimmable LED lamps can extend to nearly 100,000 hours.
    • Lifespan varies based on usage, with facilities running lights 24/7 potentially achieving six years of longevity, while offices using lights 60 hours a week could see up to 15 years.
  2. LED Degradation:

    • Unlike incandescent lamps, LEDs don't abruptly fail but gradually lose output over time.
    • Manufacturers rate LED lighting using metrics like B50-L70, indicating when 50% of bulbs will reach 70% brightness during their lifespan.
  3. Factors Affecting LED Lifespan:

    • Quality of components significantly influences LED lifespan, with poor-quality LEDs more prone to operational failure.
    • Electrical Over Stress (EOS) occurs when LEDs receive more power than recommended, often due to poor design or sub-quality drivers.
    • Exposure to extreme temperatures and high humidity levels can impact LED lifespan.
  4. Signs for LED Replacement:

    • Traditional lights burn out when no longer functional, while LEDs gradually become dimmer.
    • Diminished lighting output can lead to eye strain, headaches, and impact facility safety.
  5. LED Replacement Process:

    • Initial LED upgrades may have involved retrofitting existing fixtures with LED bulbs, but integrated LED fixtures are now more common.
    • Compatibility is crucial when replacing existing LED lights, and working with distributors can ensure optimal replacements.
    • Integrated LED solutions are often preferred for efficiency and performance.
  6. When to Consider LED Replacement:

    • After about 10 years, a facility might need LED replacement, especially if lighting isn't optimal or the facility undergoes a transformation.
    • Consulting with lighting professionals is recommended for insights into the best LED choices.
  7. Expert Consultation:

    • With over four decades in the lighting business, an experienced team can provide valuable insights into LED technology and guide decisions for warehouses, offices, and industrial settings.

In conclusion, staying informed about LED lifespan, degradation, factors influencing longevity, and the replacement process is crucial for making informed decisions, and seeking expert advice ensures optimal choices for any facility's lighting needs.

When Should I Replace My LED Lighting? - Starbeam Lighting (2024)
Top Articles
Latest Posts
Article information

Author: Duane Harber

Last Updated:

Views: 5656

Rating: 4 / 5 (71 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Duane Harber

Birthday: 1999-10-17

Address: Apt. 404 9899 Magnolia Roads, Port Royceville, ID 78186

Phone: +186911129794335

Job: Human Hospitality Planner

Hobby: Listening to music, Orienteering, Knapping, Dance, Mountain biking, Fishing, Pottery

Introduction: My name is Duane Harber, I am a modern, clever, handsome, fair, agreeable, inexpensive, beautiful person who loves writing and wants to share my knowledge and understanding with you.